(For AC fan motor) (For B05, 07, 10, 13, 16K)
<Inspection procedure>
1. Remove the front panel. (Remove 2 screws.)
2. Remove the cover of the fan motor lead wires.
3. Check AC voltage with CN10 connector while the fan motor is rotating.
NOTE :
• Using a tester, measure the resistance value of each winding coil.
• Use a thin test rod.
SJM-240-25 (RAS-B05, 07, 10, 13)
SJM-240-35 (RAS-B16)
• Do not disconnect the connector while the fan motor is rotating.
• For P.C. board side, proceed to the item "Only indoor fan does not operate"
of "Judgment of Trouble by Every Symptom".
WHI
5
CN10
BLK
3
RED
1
BRW
3
CN11
GRY
2
YEL
1
P.C. board
Position (P.C. board)
Between
(Black) -
3
1
Between
(Black) -
3
5
Between
(Red) -
(White)
1
5
3
3
5
5
1
1
3
3
2
2
1
1
Resistance value (RAS-B05, 07, 10, 13)
(Red)
120.6 ± 8.4 Ω
(White)
244.2 ± 17 Ω
364.8 ± 25.5 Ω
- 94 -
FILE NO. SVM-19001
Resistance value (RAS-B16)
115.6 ± 8. Ω
146.2 ± 10.2 Ω
261.8 ± 18.3 Ω