10-4-3. Draining the Water

• Holes are provided on the base plate of the
outdoor unit to ensure that the defrost water
produced during heating operations is drained off
efficiently.
If a centralized drain is required when installing the
unit on a balcony or wall, follow the steps below to
drain off the water.
1. Proceed with water-proofing by installing the
water-proof rubber caps in the 2 elongated holes
on the base plate of the outdoor unit. [How to
install the waterproof rubber caps]
1) Place four fingers into each cap, and insert
the caps into the water drain holes by pushing
them into place from the underside of the base
plate.
2) Press down on the outer circumferences of
the caps to ensure that they have been
inserted tightly.
(Water leaks may result if the caps have not
been inserted properly, if their outer
circumferences lift up or the caps catch on or
wedge against something.)
Drain nipple
Fig. 10-4-3
Water-proof rubber caps
(supplied with the outdoor unit)
Base plate
2. Install the drain nipple and a commercially
available drain hose (with 16 mm inside
diameter), and drain off the water.
(For the position where the drain nipple is
installed, refer to the installation diagram of the
indoor and outdoor units.)
• Check that the outdoor unit is horizontal, and
route the drain hose at a downward sloped
angle while ensuring that it is connected tautly.
Base plate
Do not use ordinary garden hose, but one can
flatten and prevent water from draining.
- 67 -
FILE NO. SVM-19001
Drain nipple
Commercially available
drain hose
Fig. 10-4-4