Refrigerant Cycle Diagram - Toshiba RAS-B05J2KVG-E Service Manual

Hide thumbs Also See for RAS-B05J2KVG-E:
Table of Contents

Advertisement

7-1. Refrigerant Cycle Diagram

RAS-B05J2KVG-E / RAS-05J2AVG-E
RAS-B07J2KVG-E / RAS-07J2AVG-E
RAS-B10J2KVG-E / RAS-10J2AVG-E
Pressure measurement
P
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
4-way valve
TS
Temp. measurement
7. REFRIGERANT CYCLE DIAGRAM
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
KSK75D43UEZA
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
Temp. measurement
T1
TC
TA
TO
Split capillary
TE
05k and 07k Refrigerant amount : 0.40kg
NOTE :
- 25 -
FILE NO. SVM-19001
Max.
Min.
Chargeless : 15m
Strainer
Pulse Modulating
valve at liquid side
Strainer
10k Refrigerant amount : 0.43kg
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
: 15m
: 2m