To disable the priming feature on the pump and let automation system control the pump:
1. Open the lid on the LCD screen of the pump.
2. Verify the green power LED is on. Press the MENU button. Settings is displayed.
3. Use the DOWN arrow button to scroll to "Priming".
4. Press the Select button. The factory default is set to priming "Enabled".
5. Press the UP arrow button until "Disabled" is displayed.
6. Press the Enter button.
7. Press the Escape button to save and exit the pump menu.
AntiFreeze
This feature allows you to set a speed (450 RPM -3450 RPM) that will run when the pump goes into
anti freeze mode. The temperature level that you wish anti freeze mode to start can also be set.
IMPORTANT NOTE: This feature is for protection of the pump. It should not be depended upon for
freeze protection of the pool. Certain situations could cause the pump to sense a different temperature
than actual air temperature. The air temperature sensor on the automation system should be used to
sense actual temperature. For example, if the pump is located indoors, the temperature of the room does
not indicate the outdoor temperature. The pump does not sense the water temperature.
To access the Anti Freeze menu:
1. Check that the green power LED is on.
2. Press the Menu button. "Settings" is displayed.
3. Use the Down arrow button to scroll to "AntiFreeze".
4. Press the Select button. The factory default is AntiFreeze "Enabled".
5. To disable AntiFreeze. Press the Select button, "Enabled" will highlight.
6. Use the Up arrow button. "Disabled" is displayed.
7. Press the Enter button.
To program AntiFreeze when enabled:
8. Press the Down arrow button.
9. Press the Select button to change the setting. The cursor will highlight the fi rst column
(ones).
10. Use the Up or Down arrow button to select 450 - 3450 RPM.
11. Press the Enter button to save the setting.
12. Press the Down arrow button. "Pump Temperature" is displayed.
pump will activate AntiFreeze. The factory default is 40° F (4.4° C).
13. Press the Select button to change the setting. The cursor will highlight the fi rst column
(ones).
This setting can be changed from 40° F to 50° F (4.4° C - 10° C).
14. Press the Enter button to save the setting. Note: To cancel any changes, press the Escape
button to exit without saving.
15. Press the Escape button to exit.
"Set Speed" is displayed. The factory default is 1000 RPM.
IntelliPro
This is the temperature the
®
Variable Speed Pump Installation and User's Guide
19
Need help?
Do you have a question about the IntelliPro Variable Speed and is the answer not in the manual?
Questions and answers