Page 2
Cased Well Installation Add a tee to the driven pipe and run the pipe horizon- tally to the pump, making sure that it slopes gradually Connect a foot valve to the first length of suction pipe, up to the pump to avoid air traps. For long horizontal and lower the pipe into the well.
Air Volume Control for details on installa- at 75 PSI. tion and operation. Horizontal Piping When Sta-Rite Con-Aire ® tanks are used, no air volume control is necessary. This tank contains a permanent In a horizontal offset installation, elbows and horizontal precharge of air.
Standard Horizontal Tanks PRIMING THE PUMP The pump can be foot mounted and connected to a Never run pump dry. Running pump with- standard tank, using standard pipe fittings. The tank out water may cause pump to overheat, damaging seal should be set on tank feet or another type of support to and possibly causing burns to persons handling pump.
Page 5
ELECTRICAL Risk of serious or fatal electrical shock. Disconnect power at service panel be- Connect motor ground fore connecting pressure switch. wire before connecting power supply wires. Do not ground to a gas supply line. Turn off power before working on pump or motor.
PUMP SERVICE Installation of Floating Seat (Figure 4C) 1. Clean polished surface of floating seat with clean Complete pump and piping system must be protected against below freezing temperature. cloth. Failure to do so could cause severe damage and voids 2.
TROUBLESHOOTING Pump Will Not Shut Off 1. Pressure switch may be out of adjustment. Motor Will Not Run 2. Ejector nozzle clogged. 1. Be sure switch is on. 3. Water level in well lower than estimated, making it 2. Fuse may be blown. impossible for pump to develop sufficient pressure.
Page 8
REPAIR PARTS LIST EXPLODED VIEW “AN” SERIES - 1/3 THRU 3/4 HP 1391 1194 Figure 5 REPAIR PARTS LIST – “AN” SERIES – 1/3 THRU 3/4 HP Model and Horsepower Part ANB-30L ANC-30L AND-30L Description Used 1/3 HP 1/2 HP 3/4 HP Motor - 1/3 HP, 60 Cycle - 115/230V AS100BHL...
Page 9
REPAIR PARTS LIST EXPLODED VIEW “AN” SERIES - 1 AND 1-1/2 HP 1392 1194 Figure 6 REPAIR PARTS LIST – “AN” SERIES – 1 AND1-1/2 HP Model and Horsepower Part ANE-30L ANF-30L Description Used 1 HP 1-1/2 HP Motor - 1 HP, 60 Cycle - 115/230V A100ELL –...
TANK GROUP “AN” SERIES ON HORIZONTAL TANKS ONLY 1393 1194 REPAIR PARTS LIST PUMP MODELS ANB30H-30 Part ANB12H-30 ANC30H-30 Description Used ANC12H-30 AND30H-30 Tank - 12 Gallon U231-92 – Tank - 30 Gallon – U231-94 Hose Clamp U19-5A U19-5A Hose - 1” I.D. x 9” Lg. U74-37B U74-37B Elbow - 3/4”...
Page 11
TANK GROUP “AN” SERIES ON CON-AIRE ® TANK ONLY 1394 1194 REPAIR PARTS LIST PUMP MODELS ANB42CA-30 Part No. ANC42CA-30 Description Used AND42CA-30 Tank CA42-E Nipple U37-644P Elbow U78-796P Hose Clamp U19-5A Hose U74-37L Elbow - 3/4” NPT U78-770P Carriage Bolt - 3/8 - 16 x 1-1/4” Lg. U30-256C Lockwasher - 3/8”...
LIMITED WARRANTY Sta-Rite warrants to the original consumer of the products listed below, that they will be free from defects in mate- rial and workmanship for the Warranty Period from the date of original installation or manufacture as noted. Product Warranty Period Water Systems Products –...