Limit Switch Adjustment; Proximity Switch Adjustment - Wittke STARLIGHT Maintenance Manual

Hide thumbs Also See for STARLIGHT:
Table of Contents

Advertisement

Limit Switch Adjustment

To adjust the limit switch:
1.
Loosen the limit switch nut.
2.
Move the lever arm to the approximate position where the switch is to be triggered.
3.
Tighten up the nut.
4.
To fine tune the adjustment, loosen the nut slightly.
5.
With a flathead screwdriver, turn the adjusting screw located at the center of the nut until a click
is heard.
6.
Tighten up the nut.
7.
Test the operation.
8.
If necessary, repeat steps 1 through 7.
N
: Limit switches are optional.
OTE

Proximity Switch Adjustment

To adjust the proximity switch:
1.
Loosen the proximity switch nuts.
2.
Adjust the proximity switch so that there is a gap of approximately 3/16 inch (4.8 mm) between
the plate (target) and the switch.
3.
Tighten up the nuts.
Electrical System 47
Switch
Nuts

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SuperdutyFeatherweight

Table of Contents