Table 6-2: (cont'd.)
REFERENCE
DESIGNATION NAME
FUNCTION
LOCATION
S8
Switch, Interlock Supplies power
Front of joystick.
to Controller.
S9
Switch, Drive/Lift Supplies power to
Controller
Selector
High Speed circuit, bottom right.
and Drive/Lift Relay
and Motor Start
circuit when in
DRIVE Position.
S10,11
Switches, Steering Supplies power to
Rocker actuator on
either Right or Left
top of Controller
Steer Valve Solenoids. Joystick, switch
bodies inside
Joystick handle.
S12
Switch, Chassis
Provides power to
Chassis Control
Lift
either UP or Down Panel.
circuits.
SNSR
Sensor, Tilt
Cuts power to Tilt
Inside Tilt Sensor
Alarm Relay when
Electrical Box.
Platform is on slopes
of 2° side to side and
2° fore and aft to
activate Tilt Alarm.
SOL1
Solenoid, Right
Shifts Steer Valve
Coil closest to
Steer (coil)
to RIGHT turn
block on left side
position.
of Manifold Block.
SOL2
Solenoid, Left
Shifts Steer Valve
Coil farthest from
Steer (coil)
to LEFT turn
block on left side
position.
of Manifold Block.
SOL3
Solenoid, Reverse Shifts Forward/
Top of Manifold
(coil)
Reverse Valve to
Block towards
reverse position.
right side.
SOL4
Solenoid, Drive
Closes Drive Dump
Top center of
Dump (coil)
Valve.
Manifold Block
towards front.
SOL5
Solenoid, Lift
Shifts Drive/Lift Valve Top center rear of
(coil)
to Lift position.
Manifold Block.
SOL6
Solenoid, Down
Opens Down Valve. Base of Lift
(coil)
Cylinder.
SOL7
Solenoid, High
Shifts High Speed
Top center left of
Speed (coil)
Valve to High Speed Manifold Block.
position.
SOL8
Solenoid, PHP
Extends
Aux. Manifold
Down
Pothole Cylinders
block in Control
Module.
SOL9 &
Solenoid, PHP
Retracts
On Pothole
SOL10
Up
Pothole Cylinders
Protection
cylinders.
SOL8
Solenoid, PHP
Extends
Aux. Manifold
Down
Pothole Cylinders
block in Control
Module.
SOL9 &
Solenoid, PHP
Retracts
On Pothole
SOL10
Up
Pothole Cylinders
Protection
cylinders.
SOL11 &
Solenoid, Series
Shifts Series/Parallel Center of Chassis
SOL12
Drive
Valve from Hi torque between modules.
Parallel to Hi speed
Series.
X-Series Work Platform