Bartec APEXmpc Operating Instruction And Safety Manual page 82

Manual ex p control unit
Table of Contents

Advertisement

Ex p control unit
Motor purge controller
10.4.2.2 Warning messages
Rev. 0
Status
Code
00000005
The bypass has been activated on the control unit.
00000006
The main switch or jumper HS_IN / HS_OUT is not closed.
00000007
Setpoint p2 "Pre-alarm" is not reached.
00000008
Setpoint p4"Maximum pressure – operation" is exceeded
00000009
Setpoint p5 "Maximum pressure – purging" is exceeded
0000000A
Setpoint temperature at sensor 1 is exceeded
0000000B
Setpoint temperature at sensor 2 exceeded
0000000C
Setpoint temperature at sensor 3 exceeded
01-37A2-7D0003_Operating instructions_MPC_20210923_0_en.docx
Plain text
Bypass active
Door contact / main switch open
p2 is not reached
p4 exceeded
p5 exceeded
Temperature at sensor 1 is exceeded
Temperature at sensor 2 is exceeded
Temperature at sensor 3 is exceeded
Maintenance and repair