Operation
Page 48 of 96
Procedure:
01-37A2-7D0003_Operating instructions_MPC_20210923_0_en.docx
Open the network settings of the LAN interface on the
PC/laptop.
Call up the properties of the LAN connection by
selecting the "Properties" button.
Call up Internet protocol version 4 (TCP/IP4) with a
double click.
Properties of the Internet Protocol Version 4 (TCP/IPv4):
Change "Obtain IP address automatically" to "Use the
following IP address" by clicking on it.
Enter IP address 192.168.11.99 at "IP address".
Enter subnet mask 255.255.0.0.
Confirm entries with OK.
Open the settings for the network adapter by clicking
the "Configure..." button.
Select the "Speed & Duplex" function in the left field
"Property" by clicking on it.
Set "Value" in the right field to "100 Mb Full" by clicking
and selecting from the drop-down menu.
Confirm changes with "OK".
Confirm properties with OK and close the status
window of the LAN connection with "Close".
Ex p control unit
Motor Purge Controller
Rev. 0