B. TROUBLE SHOOTING
System operates abnormal.
Of that user mistake, memory (SRAM) is damaged, or the system is defective of the
Cause
device.
1. Check BAT connection Switch(place template hole of reverse side).
You have to push up the Switch, and system initialize before system installation.
Solution
gure: DIP SWITCH SETTING
Fi
2. If the trouble remains after checking the above, contact a designated service center.
Broken or abnormal letters shown on the LCD, when powered on.
SRAM backup battery problem or LCD module problem
Cause
1. Initialize the controller
- Connect the cyan wire, pink wire and black wire together.
- Switch the main power on and press <1> key.
- Check if the LCD shows the message "Initialize END" "turn off Power...".
- Switch main power OFF.
- Separate 3 wires (pink, cyan and black (GND) ).
Solution
- Switch main power ON again.
* Aware that all the default setting values will be restored and data memory will
be cleared. (ID data clear/Event data clear/ Time Schedule data clear/ etc.)
2. Set up the date and time on SETUP MENU F1->SYS INITIALIZE and SETUP MENU
F1->TIME SETTING.
3. If you still have problems, please contact a designated service center.
☞ Randomly changed value of in/out define from previously setting value after power reset.
Discharge of RAM Back-Up battery / Problem during the main power off.
Cause
1. Check if the Back-Up Battery Jumper has been shortened.
2. Check if the voltage of Back-Up Battery is over 3.6V.
3. If it is over 3.6V, make initialization process as below.
- Connect the cyan wire, pink wire and black wire together
- Main power ON.
- Enter key <1>.
- Check if the LCD shows message of "Initialize END" "turn off Power...".
Solution
- Main power OFF
- Separate 3 wire(pink, cyan and black(GND))
- Main power ON again.
* Aware that all the default values are restored and data memory is cleared.
(ID data clear/Event data clear/ Time Schedule data clear etc.)
4. Define IN/OUTPUT value as intend and keep the main power on more than 5 days.
5. If after all the above, the problem remains, please contact a service center.