10. Basic Settings

10.1 INITIALIZATION OF 505R
Connect the cyan, pink and black wires (they are seen from the rear view) together and Power
on the unit. If you want hardware initializing, press Enter key <1>.
After initializing – Put the main power OFF and separate 3 wires (Pink, cyan and black(GND) ).
Afterwards put main power ON again.
Power on
Initialize OK?
0: NO 1: Yes
<1> key enter?
"Initialize Com."
"Turn OFF Power..."
Power off
System initialization completion
10.2 HOW TO ENTER THE SET-UP MENU
To set up or to change the 505R settings, you have to enter the SETUP MENU first. To do so,
press the <0> key eight times for the Master ID (Default setting "00000000") and the <ENT>
key from the Keypad. Then you can get into SETUP MENU. There are four main SETUP
MENUS and you first get into [SETUP MENU F1]. You can move to another SETUP MENU by
pressing the<F1> key for [SETUP MENU F1], <F2> key for [SETUP MENU F2], <F3> key for
[SETUP MENU F3] and <F4> key for [SETUP MENU F4]. There are several SUBMENUS in
the main SETUP MENU and you can scroll up and down the SUBMENU by pressing <4> and
<6> key in the main SETUP MENU. If you don't press any key for 60 seconds or if you press
the <ESC> key, 505R will exit the SETUP MENU and return to normal operation. You can also
change the Master ID in the [SETUP MENU F1].
In the case of SR505, Press ten times the <0> key (Default setting "0000000000") to enter
the SETUP MENU.
Yes
If you turn on the system power
after connected 3 wires (pink, cyan
and black(GND)), you can enter
into system initialize mode.
NO
Normal Operation
Disconnect 3 wires ( pink, cyan,
black) .