Gryphon Configuration

Gryphon Configuration Settings

Keypad Enable/Disable
The Gryphon PreScan model has a 3-key keypad (up, down and enter) and a display that allows
PreScan operators to use features such as basket browsing and deletion of items in the basket.
The keypad can be disabled if desired, to prevent accidental misuse by operators or checkers
(roving/assistance).

Set Indicators

Indicators such as display prompt messages and beeper sounds can be programmed in several
different configurations. The prompt can be set to occur with or without an accompanying beep
tone, and the order of the keypad Yes/No buttons can be defined as well.
The prompt message is used during many basket operations. The following prompts can be
enabled or disabled:
1. Close open basket (with programming label)
2. Clear items in basket
3. Delete open basket
4. Delete all baskets
5. Next Basket Session Prompt (Reading a new control card closes the current basket and
6. Delete the expired basket on inactivity
Basket Operations
See
20
Enable
When the Keypad is disabled, some configuration items will be disabled.
Next Basket Session Prompt
See
for more information.
opens a new one)
on page 22 for more information about these and other basket functions.