Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
4.4 Set the Presets
Please set the presets according to steps below to improve the accuracy of fire detection.
Steps
1. If the presets located in different areas, you can set 6 presets in two areas as the example
showed below.
2. Divide the scan area into three parts and set a preset every 120°. The black numbers are
presets, and the red numbers are scan areas.
3. Set the presets according to the sequence of patrol path: 1->2->3->1->4->5->6->4.
Note
• When set the presets, you should adjust the zoom ratio to view the image of both optical
channel and thermal channel clearly.
• The recommended zoom ratio of optical channel and patrol speed shows in the table below.
Figure 4-2 Set the Presets for fire detection
15