Set Rules - HIKVISION DS-2TD6237-50H4L/W User Manual

Thermal & optical bi-spectrum ptz network camera
Table of Contents

Advertisement

Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
Note
If you want to show the name on the image, check Display Scene Name.
4. Check Track to enable the target tracking function for the scene.
5. Optional: Check Limited Tracking and set the auto tracking range.
The camera channel tracks a target only within the set auto tracking range.
1) Control the PTZ buttons to a desired scene and click Set Up Limit to save the position as the
scene's upper boundary.
2) Repeat to set the left, right and lower boundaries of the scene.
6. Set other tracking parameters.
Tracking Duration
Set the duration of tracking. If the value is selected as 0, the tracking duration will not be
limited.
Zooming Ratio
It is the zoomed-in level when the camera channel is tracking a target.
Go to Configuration → VCA → Zooming Ratio , select a scene from the drop-down list, and
control the zoom in/out buttons to get a desired zooming level, and save the settings.
Post-tracking
Set the duration of automatic tracking of the target after it stops.
Go to Configuration → VCA → Advanced Configuration , and set parameter.
7. Click Save.

5.3.2 Set Rules

The device can detect whether there is any target breaking the VCA rules. The optical camera will
track the target or the device will alarm when the VCA rule is triggered.
Steps
1. Go to Configuration → VCA → Scene Configuration → Scene x → Rule .
2. Click
to add a new rule.
3. Enter the rule name, and click the drop down menu to select Rule Type.
Note
Each scene can be configured with different rule types. Up to 8 rules can be set for one scene.
Line Crossing
If any target move across the setting line, the alarm will be triggered. You can set the crossing
direction.
Intrusion
22