Installation Instructions
The appliance is delivered with a certified power cord and plug: it is
prohibited to manipulate them or modify them.
Potential Equalising Connection
•
The potential equalising connection between various appliances should be
executed at the connection clamp, marked with
•
The connection clamp is found at the back of the appliance.
•
This clamp renders it possible to connect a potential equalising cord with section
of 4 mm² – 10 mm².
Adjustment of Door Locking Pin
After placing the appliance in the selected location, check the closing mechanism
and position of door seals on the thermal processing chamber.
Fig. 6
After adjustment, re-tighten the bolt making sure that the lock anchor is pointed
downwards.
116622
symbol.
It is possible to adjust the depth of the
locking pin in order to assure that the
chamber is properly locked during thermal
processing.
It is possible to adjust the door pressure
against the seal. Screw the pin in to
increase the pressure or screw it out to
reduce the pressure (Fig. 6).
EN
21 / 40