Installation Instructions
Water Connection
Make sure that the potable water connection is located close to the appliance.
In new installation is carried out, before the appliance is connected to water
supply system, drain sufficient amount of water to prevent contamination of
magnetic valves.
Fig. 4
ATTENTION!
Hydraulic water pressure should be max. 3 bar.
If the water pressure in the installation is higher, install pressure reducer
upstream of the appliance.
The minimum water pressure should be exceeding 1.5 bar to assure correct
operation of the appliance.
In order for the device to operate properly and to avoid limescale deposits in the
thermal processing chamber, drinking water of hardness up to 5° d.H (according
to German scale) must be available.
ATTENTION!
With water hardness exceeding 5° d.H (according to German scale) a
suitable water softening device must be installed upstream of the
appliance.
116622
Fix the included water supply hose to
the appliance's connection element
(3/4"). The connection is located
under the appliance, to the right
(Fig. 4).
Connect the other end of the water
pressure hose to cold water
installation and install a closing valve
and a filter between them.
Make sure that the closing valve is
installed in an easily accessible place
for the user.
EN
19 / 40