To Erect/Suspend; Controls Before Operational Start-Up; Operation; Mains Connection - FLORABEST FTP 400 C2 Translation Of Original Operation Manual

Submersible water pump
Table of Contents

Advertisement

Available languages

Available languages

GB
tion systems, cut off the three top
connections directly above the
G 1 ½ " tube thread.
The measurement of the maximum
performance data takes place
under optimal conditions, such as
a straight, direct exit. The angle
adapter (
stopper (
To increase pump output, the backflow
stopper (10) may be taken out of the angle
adapter (11) (see
stopper"). This is particularly recom-
mended for hose connections smaller than
1". Please bear in mind that the water may
then flow back during pumping, or in the
event of a power cut.

To erect/suspend

The pump can be erected or sus-
pended in the water.
The cord (
delivery contents may be used to
suspend and/or extract the pump.
The pump shaft should have the dimen-
sions 40 x 40 x 50 cm at least, so that the
float switch can move freely.
Fix the nylon rope (12) onto the car-
rying handle (1).
Ensure that the equipment is
not hung up or held by the
mains cable. There is a risk
of electric shock from dam-
aged mains cables.
Note that, over time, dirt and sand
may collect on the bottom of the
shaft, which could damage the
36
11) and the backflow
10) may reduce output.
"replacing backflow
12) contained in the
pump.
We recommend placing the pump
on a brick or a grid.
If the water level is too low, the silt in
the shaft can quickly dry out and im-
pede the pump when warming up.
Controls before operational
start-up
• Check that the float switch is
working (see chapter: "Opera-
tion").
• Check that the pump is resting
on the pit base
• Check that the pressure line has
been attached properly
• Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
ficiently fused (at least 6 A). In-
sert the pump plug into the plug
socket and the pump is ready for

operation.

• Make sure that moisture or water
never come in contact with the
mains connection.There is a risk
of electrocution.
Operation

Mains connection

The submersible water pump acquired by
you is already provided with an grounded
plug.
The equipment is designed for con-
nection to an earthed wall socket with a
residual current operated device (RCD
switch) at 230 V ~ 50 Hz.
Only start to operate the device
after all the above conditions have
been observed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

96809

Table of Contents