RUGGEDCOM RSG2100PF
Installation Guide
Technical Specifications
This section details the specifications and operating conditions of the device.
CONTENTS
•
Section 5.1, "Power Supply Specifications"
•
Section 5.2, "PoE Power Supply Specifications"
•
Section 5.3, "Failsafe Relay Specifications"
•
Section 5.4, "Supported Networking Standards"
•
Section 5.5, "Copper Ethernet Port Specifications"
•
Section 5.6, "Fiber Optic Ethernet Port Specifications"
•
Section 5.7, "Operating Environment"
•
Section 5.8, "Mechanical Specifications"
•
Section 5.9, "Dimension Drawings"
Section 5.1
Power Supply Specifications
The RUGGEDCOM RSG2100PF can be equipped with the following power supplies:
CAUTION!
Electrical hazard – risk of power supply failure or damage to the device. Make sure power input to the
device is within the specified input range. If power input is too high, damage to the power supply may
occur. If power input is too low, damage to the device may occur.
NOTE
For specifications on the PoE power supply, refer to
Power Supply Type
24 VDC
48 VDC
d
HI (125/250 VDC)
d
HI (110/230 VAC)
a
(F) denotes fast-acting fuse
Power Supply Specifications
Input Range
Minimum
Maximum
10 VDC
36 VDC
88 VDC
300 VDC
85 VAC
264 VAC
Section 5.2, "PoE Power Supply
Internal Fuse Rating
36 VDC
6.3 A(F)
72 VDC
3.15 A(T)
2 A(T)
2 A(T)
Chapter 5
Technical Specifications
Specifications".
Maximum Power
ab
c
Consumption
28 W
29