Technical specifications

6.1

GPRS/EDGE router SCALANCE M874-2

Article number
Ethernet interface
Attachment to Industrial
Ethernet
Wireless interface
Antenna connector
Frequency band
EGPRS
GPRS
GSM (CSD dial-in)
SMS (TX)
Electrical data
SCALANCE M874, M876
Operating Instructions, 08/2018, C79000-G8976-C331-08
M874-2
6GK5 874-2AA00-2AA2
Quantity
2
Design
RJ-45 jack
Characteristics:
Quantity
1
Design
SMA socket (straight)
Impedance
50 Ω nominal
Antenna cable
Cable length < 30 m
GSM
850 MHz = GSM 850
900 MHz = GSM 900
1800 MHz = GSM 1800
1900 MHz = GSM 1900
Properties
Multislot class 12, end device class B
Transmission speed •
Properties
Multislot class 12, end device class B, coding
scheme 1 ... 4
Transmission speed •
Properties
Radio Link Protocol (RLP) V.110, non-
transparent
Transmission speed up to 14.4 kbps
Properties
Text mode, SMSoverIP
10/100BASE-T
Ethernet IEEE 802.3
10/100 Mbps
Coding scheme downlink: CS 1 ... 4, MCS 1
... 9
Coding scheme uplink: CS 1 ... 4, MCS 1 ... 9
Downlink: up to 237 kbps:
Uplink: up to 237 kbps:
Downlink: up to 85.6 kbps.
Uplink: up to 85.6 kbps.