RUGGEDCOM RX1100P
Installation Guide
Technical Specifications
The following sections provide important technical specifications related to the device and available modules:
•
Section 4.1, "Power Supply Specifications"
•
Section 4.2, "PoE Power Supply Specifications"
•
Section 4.3, "Failsafe Relay Specifications"
•
Section 4.4, "Copper Ethernet Port Specifications"
•
Section 4.5, "Fiber Ethernet Port Specifications"
•
Section 4.7, "IRIG-B Output Specifications"
•
Section 4.8, "Operating Environment"
•
Section 4.9, "Mechanical Specifications"
Section 4.1
Power Supply Specifications
NOTE
For specifications on the PoE power supply, refer to
Power Supply Type
12 VDC
24 VDC
48 VDC
d
HI (125/250 VDC)
d
HI (110/230 VAC)
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
d
The HI power supply is the same power supply for both AC and DC.
Power Supply Specifications
Input Range
Minimum
Maximum
10 VDC
36 VDC
36 VDC
59 VDC
88 VDC
300 VDC
85 VAC
264 VAC
Section 4.2, "PoE Power Supply
Internal Fuse
Isolation
ab
Rating
6.3 A(F)
1.5 kVDC
3.15 A(T)
2 A(T)
4 kVAC, 5.5 kVDC
Chapter 4
Technical Specifications
Specifications".
Maximum Power
c
Consumption
25 W
33