Instructions of Safety Standard selection when power-up

1. Attentions before the operation:
Only perform this operation when the voltage value displayed on Omnik inverter's LCD falls
between 80V and 300V for 1kW inverter or between 150V and 450V for 1.5kW inverters.
Only perform this operation when the accumulative generated electricity is less than 1KWh.
2. Operation steps are as following:
2.1 Power on the inverter with only DC side connected, while disconnecting cables of AC side.
2.2 Press the Function button until the LCD displays inverter's model and hold the button for 5
seconds or more when the LCD displays the current Safety Standard. Change the standard by
pressing the Function button one at a time.
Function button
2.3 When the LCD displays your desired Safety Standard, hold the Function button for 5
seconds or more until it shows "Safety Standard OK".
2.4 The Safety Standard setup is now completed.