7.3

Instructions of Safety Standard selection when power-up

1. Attentions before the operation:
Only perform this operation when the accumulative generated electricity is less than 1kWh.
2. Operation steps are as following:
a) Power on the inverter with AC side connected.
b) Press the Function button until the first line of LCD displays " Standard " ,for example
"Italy".
c) Hold the button for 5 seconds or more until the first line of LCD displays "Set". Change
the standard by pressing the Function button one at a time.
d) When the LCD displays your desired Safety Standard, hold the Function button for 5
seconds or more until the first line of LCD shows "Set OK".
e) Cut down the AC power of the inverter and wait for 10 minutes .Then power on the
inverter with AC side connected again .The safety standard has been changed now.
Function button
43