OPERATING THE FIRE
a)
Light the pilot by depressing the control knob at the "off" position and
turn anti-clockwise (with the control depressed) to the second position
marked *.
b)
When the pilot lights, (pilot can be seen through the central ceramic
plaque) hold the control knob down for 10 seconds.
c)
If the pilot fails to light, repeat the ignition sequence and hold in the
control knob for slightly longer.
d)
When the pilot has lit, release the control knob from the depress
position, depress slightly again and turn the control anti-clockwise to the
HIGH position and check for clearance of combustion products as
detailed below.
WARNING
If the fire goes out for any reason or is turned off and it is
necessary to relight the fire it is important to allow the fire to cool
for 3 minutes before attempting to re-light it.
SPILLAGE MONITORING SYSTEM
This appliance is fitted with a spillage monitoring system which shuts down the fire
if the evacuation of combustion products from the fire is affected by a partially or
fully blocked flue.
If this system operates the fire will go out. If this occurs, leave the fire for at least
three minutes then follow the lighting procedure as described in the previous sec-
tion. In the event of repeated operation a CORGI registered gas installer
must be called to investigate and rectify the cause.
CLEANING - WARNING
Before attempting any cleaning operation ensure that the fire has been allowed to
fully cool.
CLEANING THE CERAMICS
We do not recommend regular cleaning of the ceramics as these are fragile and
damage may result. They make be cleaned occasionally however as described on
page None of these parts must be washed or exposed to any cleaning agents
or water.
Any damaged parts must be replaced by contacting your dealer or telephoning
BFM Europe Ltd. on the number stated on the rear cover of this book. The
ceramics must only be replaced with a complete and genuine replacement set and
the fire must never be run with the wrong number or damaged ceramics. The
ceramics must be carefully re-assembled as stated in the following section.