Summary of Contents for Crestron Isys TPS-5000L

  • Page 1 Crestron Isys™ TPS-5000L 12 Inch Lectern/Wall Mounted Touchpanel Operations Guide...
  • Page 2 This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2003 Crestron Electronics, Inc.
  • Page 3: Table Of Contents

    Crestron Isys™ TPS-5000L Contents 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L Introduction ... 1 Features and Functions ... 1 Specifications ... 3 Physical Description... 4 Industry Compliance ... 7 Setup ... 7 Network Wiring... 7 Identity Code ... 8 Configuring the Touchpanel...
  • Page 5: Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ Tps-5000L

    TPS-5000L Introduction Features and Functions The TPS-5000L series packs all the power and performance of an Isys panel in a stylish lectern or wall-mount model. Its size and capabilities make it perfect for the conference room and home theater. These touchpanels are available with two different faceplate colors: black, or white.
  • Page 6 12 Inch Lectern/Wall Mounted Touchpanel TPS-5000L Functional Summary (continued) Multiple graphics can be displayed on the TPS-5000L without any shift in color depth or quality. The touchpanel can support real-time video with the optional TPS-VIDL-1 or TPS-VIDL-2 cards, RGB computer graphics with the optional TPS-XVGAL RGB Interface card, and 10/100 BaseT TCP/IP network communications with the optional TPS-ENETL Ethernet module.
  • Page 7: Specifications

    Crestron Isys™ TPS-5000L Specifications The following provides a summary of specifications for the TPS-5000L touchpanel. Specifications for the TPS-5000L Touchpanel (continued on next page) Operations Guide - DOC. 5783A 12 Inch Lectern/Wall Mounted Touchpanel SPECIFICATION Power Requirements 20 Watts (0.83 Amp @ 24 VDC)
  • Page 8: Physical Description

    These control systems do not support loading of firmware or VT Pro-e files to the TPS-series panels through the RS-232 port of the control system. In order to load these files to the TPS-5000L when using these control systems, either use the RS-232 port on the TPS-5000L or use Ethernet direct to the panel (assuming the TPS-ENETL is installed).
  • Page 9 Operations Guide - DOC. 5783A 12 Inch Lectern/Wall Mounted Touchpanel 13.43 in (34.11 cm) 9.68 in (24.59 cm) 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 5 2.70 in (6.85 cm) 11.04 in 7.26 in (18.44 cm) (28.05 cm)
  • Page 10 The TPS-5000L ships with 4MB of flash and 8MB of DRAM. Additional memory by Crestron can be purchased separately and installed in the field. Refer to the latest revision of the Flash Memory for TPS User Interfaces Installation Guide (Doc. 5927) for an installation procedure.
  • Page 11: Industry Compliance

    NOTE: When installing network wiring, refer to the latest revision of the wiring diagram(s) appropriate to your specific system configuration, available from the Downloads | Product Manuals | Wiring Diagrams section of the Crestron website (www.crestron.com). When calculating the wire gauge for a particular Cresnet run, the length of the run and the power factor of each Cresnet unit to be connected must be taken into consideration.
  • Page 12: Identity Code

    EEPROM and displays the main page that has been programmed into your system. The remaining buttons on the MAIN MENU open other menus, which are discussed in subsequent paragraphs. 8 • 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L Crestron Isys™ TPS-5000L Operations Guide - DOC. 5783A...
  • Page 13: Calibration Menu

    Screen brightness may need to be altered because of ambient light conditions or personal preference. BRIGHTNESS, located in the lower left corner of the SETUP Operations Guide - DOC. 5783A 12 Inch Lectern/Wall Mounted Touchpanel 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 9...
  • Page 14 SIMPL Windows program of the Cresnet system. Matching IDs between touchpanel and SIMPL Windows program is required if data is to be successfully transferred. NET ID for the TPS-5000L is factory set to 03, and no two devices in the same system can have the same ID.
  • Page 15 Touch output (communication of touch coordinates to an external device) • Mouse input (allows a mouse to control an external device as a “touch the PC” device) • External touch screen input. 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 11...
  • Page 16 TPS-ENETL is properly installed. NOTE: IP settings are necessary only if the TPS-ENETL is installed. Serially connect a PC to the TPS-5000L via the RS-232 connector and refer to the details in the latest revision of the TPS-ENETL (Doc. 6013).
  • Page 17 Select SAVE Menu to open the Preset Menu, as shown below. To assign a format to a preset, complete the following steps: Preset Menu (Vertical Lines Portray RGB Sample) Operations Guide - DOC. 5783A 12 Inch Lectern/Wall Mounted Touchpanel 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 13...
  • Page 18 Video 1 and Video 2 will be displayed. Selection of a Video button opens the Video Menu from which the user can adjust video settings. The TPS-5000L can display video from up to four different composite video sources connected to either the 6-pin connector or the BNC connectors. However, only two composite video channels can be selected for viewing.
  • Page 19 Sharp button for sharp mode video. This mode provides maximum detail, but is more susceptible to noise in source. The text color of the selected button is red rather than black. Operations Guide - DOC. 5783A 12 Inch Lectern/Wall Mounted Touchpanel 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 15...
  • Page 20: Hardware Hookup

    CAUTION: Do not apply excessive pressure to the touchscreen display during handling (mounting/installation). Doing so can crack the screen and damage the touchpanel. Hardware Connections for the TPS-5000L (Back of the Unit is Shown) AUDIO IN AUDIO INPUT This 6-position, mini- connector provides line level, balanced and unbalanced audio input.
  • Page 21 TPS-5000L Audio Input connector. Refer to the following diagram. Wiring for Unbalanced Audio NOTE: The TPS-5000L can receive audio signals over CAT5 wiring. For additional information on audio connections over CAT5, refer to the latest version of the Crestron CAT5 Wiring Reference Guide (Doc.
  • Page 22 Refer to “RS-232 Menu” on page 11 for proper RS-232 port configuration settings. Also refer to “Appendix A: RS-232 Protocol” on page 45 for protocol details. RS-232 Pinouts 18 • 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L PIN # DESIGNATION PIN #...
  • Page 23: Touchpanel Mounting Options

    Touchpanel Mounting Options Rack Mounting There is also a rack mount kit for the TPS-5000L (known as RMK-5000). Refer to the latest version of the Installation Guide (Doc. 5852) which is available from the Crestron website (www.crestron.com).
  • Page 24 12 Inch Lectern/Wall Mounted Touchpanel Direct Mounting The TPS-5000L is a low-voltage unit that can be installed directly into a mounting surface. Each touchpanel is provided with mounting hardware and accessories, as shown in the table after this paragraph. TPS-5000L Supplied Mounting Hardware and Accessories NOTE: Refer to Appendix B: Cutout Detail of Supplied Template on page 47 for cutout dimensions.
  • Page 25 Use caution and do not crack or damage mounting surface. 14. Mate the four posts of the faceplate with the holes drilled into the mounting surface and firmly press on the faceplate over the touchpanel. 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 21...
  • Page 26: Touchpanel Removal

    Touchpanel Removal If it is necessary to remove the touchpanel after it has been installed into a mounting surface, complete the following steps in the order provided to remove the touchpanel.
  • Page 27: Programming Software

    This custom template can then be used by Crestron AppBuilder to create the final project files to be loaded into the panels. Alternatively, VT Pro-e can be used to tweak projects created with Crestron AppBuilder or develop original touchpanel screen designs.
  • Page 28: Programming With The Crestron Appbuilder

    Windows This section describes a sample SIMPL Windows program that includes a TPS-5000L touchpanel. A Join Number Remapping (JNR) program can be written to augment the functionality of the touchpanel by making some of the touchpanel’s internal functions available to the SIMPL Windows programmer.
  • Page 29 Expanded PRO2 System Tree C2Net-Device Slot in Configuration Manager To incorporate the TPS-5000L touchpanel into the system, drag the TPS-5000 from the Touchpanels | Touchpanels (Cresnet) folder of the Device Library and drop it in the System Views. The PRO2 system tree displays the touchpanel in slot 9 with a default NET ID of 03 as shown in the following illustration.
  • Page 30 In SIMPL Windows, the signal types are color-coded as follows: 26 • 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L Crestron Isys™ TPS-5000L Digital = Blue...
  • Page 31 TPS-5000L Input/Output Signals The TPS-5000L symbol provides up to 4000 digital input and output joins, 4000 analog input and output joins, and up to 999 serial input joins. The programmer selects the signal types by clicking on the appropriate button at the top of the Symbol Detail view when programming the panel.
  • Page 32: Programming With Visiontools™ Pro-E

    (recorded as WAV files). A set of pages, which make up a project, can be designed for each TPS-5000L touchpanel application. Each page contains objects such as custom control graphics, two and three-dimensional buttons, sliders, and digital readouts which allow the user to interface with the control system via join numbers.
  • Page 33: Wav File Audio Messages

    Pre-recorded WAV files for voice prompts and responses are available from Crestron. These files can be stored into and programmed for use in the touchpanel directly or may be edited with the Sound Recorder. For example, the individual files can be combined to create custom messages.
  • Page 34 12 Inch Lectern/Wall Mounted Touchpanel NOTE: WAV files (for the TPS-5000L touchpanel) can be obtained from the Crestron FTP site Since the CT/LC-1000 touchpanel accepts the same WAV file formats, only use those WAV files designated for the CT/LC-1000, TPS-2000L, or TPS-5000 touchpanels.
  • Page 35 The audio parameters of the file also appear to the right of the table. 4. Repeat steps 1 through 3 for each desired WAV file. 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 31...
  • Page 36: Reserved Join Numbers

    System Analog Reserved Join Numbers for TPS-5000L Touchpanels System Digital Reserved Join Numbers for TPS-5000L Touchpanels Audio Analog Reserved Join Numbers for TPS-5000L Touchpanels 32 • 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L JOIN # FUNCTION 17203...
  • Page 37 Video 2 17151 Video 2 17152 Video 2 17153 Video 2 Available only when TPS-VIDL-1 is installed. Available only when TPS-VIDL-2 is installed. 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 33 VALUE IN/OUT INPUT/OUTPUT INPUT/OUTPUT INPUT/OUTPUT INPUT/OUTPUT Increase INPUT...
  • Page 38 12 Inch Lectern/Wall Mounted Touchpanel Video and XGA Digital Reserved Join Numbers for TPS-5000L Touchpanels continued on next page 34 • 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L JOIN # FUNCTION 1, 2 17101 Video 1 1, 2 17102...
  • Page 39: Multibyte International Characters

    SIMPL Windows. In other words, you cannot enter Chinese character interspersed with numbers. You can enter Chinese characters or numbers in separate strings. Crestron is scheduling time to fix this in the near future and the release notes for SIMPL Windows will mention it.
  • Page 40: Uploading And Upgrading

    Communication Settings Connection of a PC to the TPS-5000L touchpanel can be direct via the RS-232 port on the touchpanel or through a control system (Cresnet). Both methods of connection provide setup for RS-232 communication.
  • Page 41 Crestron Cable Number STCP-502PC or equivalent 1. Start SIMPL Windows or VT Pro-e. 2. From the menu bar, select Tools | Viewport to open the Crestron Viewport. (If communication settings are correct, the prompt should be TPS for direct communications).
  • Page 42: Uploading A Simpl Windows Program

    .bin for CNX generation, and .csz for CNX generation with SIMPL+. 38 • 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L 1. Start SIMPL Windows. 2. Select File | Open to view the “Open” window, navigate to the SIMPL Window file (.smw), and click Open.
  • Page 43 4. To verify that the program has been transferred successfully, select Diagnostics | Report Program Information or press F7. This should display a window that provides details about the current program loaded into the control system. 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 39...
  • Page 44: Uploading A Vt Pro-E Project

    2. As shown after this step, select File Transfer | Send Touchpanel (alternatively, press Alt+T) from the Viewport menu. 3. As shown after this step, select the NET ID of the TPS-5000L touchpanel and then click OK. The “Touch Panel Transfer” window appears (refer to the subsequent graphic).
  • Page 45: Firmware Upgrade

    “Open” Window Firmware Upgrade A firmware upgrade file has the To take advantage of all the TPS-5000L features, it is important that the unit contains extension .csf. the latest firmware available. Therefore, please check the Crestron website (http://www.crestron.com/downloads/software_updates.asp) for the latest version of firmware.
  • Page 46 Select CSF File 42 • 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L 3. As shown after this step, select the NET ID of the TPS-5000L touchpanel and then click OK. The “Open” window appears (refer to the subsequent graphic).
  • Page 47: Problem Solving

    Crestron Isys™ TPS-5000L Problem Solving Troubleshooting The table after this paragraph provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. TPS-5000L Touchpanel Troubleshooting Operations Guide - DOC. 5783A 12 Inch Lectern/Wall Mounted Touchpanel...
  • Page 48: Further Inquiries

    Future Updates As Crestron improves functions, adds new features, and extends the capabilities of the TPS-5000L, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.
  • Page 49: Appendix A: Rs-232 Protocol

    Crestron Isys™ TPS-5000L Appendix A: RS-232 Protocol TPS-5000L touchpanels support panel operation via a host computer through the RS-232 port. Crestron recommends that the following serial data format is set. Suggested Serial Data Format These settings may be altered via the RS-232 Menu when configuring the touchpanel, however, doing so may prevent Crestron supplied software from operating with the touchpanel.
  • Page 50 2400 baud. Obviously, ramping several objects at once requires a baud rate several times as high. Indirect Text – TPS-5000L touchpanels support a feature that permits the text field in any user-defined button to be altered on the fly in RUN mode. This is accomplished by substituting a text pointer for the text in the button.
  • Page 51: Appendix B: Cutout Detail Of Supplied Template

    Use the alphanumeric codes in the illustration and table to obtain the cutout dimensions for the lectern mount models when mounting without the BB-5000. However, Crestron recommends that the supplied template be used to avoid error. Operations Guide - DOC. 5783A...
  • Page 52: Appendix C: Configuring The Rs-232 Port For Use

    12 Inch Lectern/Wall Mounted Touchpanel Appendix C: Configuring the RS-232 Port for Use To configure the RS-232 port of the TPS-5000L, a local PC that contains a Crestron Viewport is required. The Viewport is one of the development tools that is part of...
  • Page 53 Crestron Isys™ TPS-5000L At this point, the PC and the TPS-5000L are no longer communicating. Assuming that the touchpanel is properly connected for use (as shown in the diagram for "Communication Settings" on page 36) and the control system is connected to the PC, the setup screens can be displayed to set the NET ID and other configurations.
  • Page 54: Software License Agreement

    This Agreement may only be modified by a writing signed by an authorized officer of Crestron. Updates may be licensed to You by Crestron with additional or different terms. This is the entire agreement between Crestron and You relating to the Software and it supersedes any prior representations, discussions, undertakings, communications or advertising relating to the Software.
  • Page 55 “applets” incorporated into the Software), the accompanying media and printed materials, and any copies of the Software are owned by Crestron or its suppliers. The Software is protected by copyright laws and international treaty provisions. Therefore, you must treat the Software like any other copyrighted material, subject to the provisions of this Agreement.
  • Page 56: Return And Warranty Policies

    CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, modification, or improper installation procedures.
  • Page 57 Crestron Isys™ TPS-5000L 12 Inch Lectern/Wall Mounted Touchpanel This page intentionally left blank. 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 53 Operations Guide - DOC. 5783A...