Specifications for the TPS-5000L Touchpanel (continued)
SPECIFICATION
Enclosure
CPU
Cresnet
RS-232
Operating Temperature
and Humidity
Dimensions and Weight
(with faceplate)
1
The individual power requirements for the expansion cards are:
TPS-ENETL: 4 Watts (0.167 Amps @ 24 VDC)
TPS-VIDL-1: 7 Watts (0.29 Amps @ 24 VDC)
TPS-VIDL-2: 12 Watts (0.50 Amps @ 24 VDC)
TPS-XVGAL: 10 Watts (0.417 Amps @ 24 VDC)
2
The latest versions can be obtained from the Downloads | Software Updates section of the Crestron
website (www.crestron.com). Refer to NOTE after last footnote.
3
Crestron 2-Series control systems include the AV2, CP2, CP2E, MP2, MP2E, PAC2, PRO2, and
RACK2.
4
CNX update files are required for either CNMSX-AV/Pro or CNRACKX/-DP. Filenames for CNX
update files have a UPZ extension and ST-CP files are in one EXE or zipped UPZ file. To avoid
program problems, make certain you are using the update file with the correct suffix letter (e.g., S,
V, W, X).
5
When loading VT Pro-e files or firmware through the RS-232 port of the control system, be sure that
the baud rate is at 38400 (Cresnet speed) or lower. Otherwise, the Viewport may post the "Transfer
Failed" message.
6
These control systems do not support loading of firmware or VT Pro-e files to the TPS-series panels
through the RS-232 port of the control system. In order to load these files to the TPS-5000L when
using these control systems, either use the RS-232 port on the TPS-5000L or use Ethernet direct to
the panel (assuming the TPS-ENETL is installed).
7
WAV files reside in the touchpanel's Flash memory and will affect the amount of available space for
touchpanel screens.
8
Additional Flash memory can be purchased, refer to "Memory" on page 6. The complexity of the
control screens and the sampling of the WAV files influence memory usage.
NOTE: Crestron software and any files on the website are for Authorized Crestron
dealers and Crestron Authorized Independent Programmers (CAIP) only. New users
may be required to register to obtain access to certain areas of the site (including the
FTP site).

Physical Description

The 12 inch (30.1 cm) touch sensitive viewing screen is located on the front of the
TPS-5000L touchpanel, shown after this paragraph. The electronic hardware is
housed in a black metal enclosure. All audio, video, Ethernet, RS-232, and network
connections are made at the rear of the unit. The grill located on the front of the unit
conceals two speakers and a microphone.
Crestron Isys™ TPS-5000L
DETAILS
Black metal enclosure with injection-molded
plastic faceplate in black or white.
63MIPs Coldfire processor running Isys generation
firmware
Via 4-position Cresnet connector
RJ11 connector for console, telestrator, etc.
Default settings: 115200, 8 bit, parity none, stop
bit 1.
50º to 113º F (10º to 45º C),
10 to 90% Relative Humidity (non-condensing)
Height: 11.04 in (28.05 cm)
Width: 13.43 in (34.11 cm)
Depth: 2.70 in (6.85 cm)
Weight: 5.9 lbs (2.7 kg)