12 Inch Lectern/Wall Mounted Touchpanel
Securing Two Plates to Top and Bottom Edges of Opening
LARGE
METAL
MOUNTING
PLATE
SMALL
METAL
MOUNTING
PLATE
DRYWALL
10. Repeat steps 7 through 9 for the bottom horizontal edge of the opening.
11. Attach the network cable and other RS-232, audio, video, or Ethernet
cables in the wall to the appropriate connector on the back of the
touchpanel. Refer to "Network Wiring" on page 7 for network wiring
details. Information about the Net, RS-232, microphone, and audio
input connectors are located in "Hardware Hookup" on page 16. For
wiring the other connectors, refer to the appropriate Operations &
Installation Guide for each expansion card.
12. Position the touchpanel (less the faceplate) into the opening and secure
with eight pan head screws, supplied. Tighten by hand; do not fully
tighten screws.
Positioning Touchpanel into Opening
POSITION
AND SECURE
TOUCHPANEL
INTO OPENING
NOTE:
WIRING NOT SHOWN
FOR CLARITY
DRYWALL
13. Use the #2 Phillips screwdriver and fully tighten all 12 pan head
screws. Use caution and do not crack or damage mounting surface.
14. Mate the four posts of the faceplate with the holes drilled into the
mounting surface and firmly press on the faceplate over the touchpanel.
12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 21
TWO PAN
HEAD
SCREWS
(MOUNTS PLATES
IN TWO CENTER
TAPPED HOLES)