Mounting; Technical Data - Bosch DCN Next Generation Installation And User Instructions Manual

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN NG | Installation and User Instructions | Section 2 | Interpretation Equipment
7.6

Mounting

To install the board, first mount and secure it in a
convenient position. The DCN cable of the data
distribution board connects directly to the system. To
extend this cable, extension cables of type LBB4416/xx
can be used (see also section 7.3.2).
Caution
Use an anti-ESD bracelet to prevent
electrostatic discharges when handling the
printed circuit board.
Bosch Security Systems | 2004-03 | 9922 141 70521en
7.7

Technical data

7.7.1
Physical characteristics
Dimensions (H x W):
100 x 200 mm
Weight:
300 g
7.7.2
Power consumption
Power consumption:
2 W
7.7.3
Climate conditions
Temperature:
5 to 45 °C (operating)
-20 to 70 °C (transport, handling and storage)
Relative humidity:
15 to 90% (operating)
5 to 95% (transport, handling and storage)
Air pressure:
600 to 1100 hPa
7.7.4
Electrical characteristics
Supply voltage (DCN) or external:
10 - 40 V(DC)
Current consumption (DCN):
< 50 mA at 40 V
Remote output open collector voltage (16):
< 50 V (freewheeling diodes at the outputs are
provided permitting the connection of relays).
Remote output collector current (16):
< 125 mA
Remote input voltage:
0 to 5 V logic CMOS level
7.7.5
DCN connections
Number of connections:
1x DIN-6 female DCN socket
1x DCN cable (2 m) with male connector
Position:
Component side
en | 58