DCN NG | Installation and User Instructions | Section 5 | System Installation
26.8.4 Example
LBB 4114/00
Trunk Splitter
LBB 4114/00
Trunk Splitter
LBB 4114/00
Trunk Splitter
LBB 4124/xx
Channel Selector
figure 26.4: Example DCN
Bosch Security Systems | 2004-03 | 9922 141 70521en
100 m (328 ft)
Regenerative
tap-offs
100 m (328 ft)
Regenerative
tap-offs
240 m (787 ft)
Max. P = 19 W at
240 m (787 ft) acc.
to the graph.
The first two trunk
splitters use 2.6W,
therefore the power
left at this point
is 13.8 W.
LBB 4114/00
Trunk Splitter
250 m (820 ft) (max)
5 x 2 = 10 m
(32.8 ft)
LBB 4100/00(D)
Central Control Unit
RS 232
Port 1
Audio In 1
Audio Out 1
RS 232
Port 2
Network
Trunk
1
2
1
2
Fault
NC C C NO
48V
48V
LBB 4106/00(D)
Extension Power Supply
Trunk
Tap-off
In
Out
Out
Out
Trunk outlet
LBB 4114/00
Trunk Splitter
Regenerative
tap-offs
LBB 4114/00
Trunk Splitter
LBB 4114/00
Trunk Splitter
LBB 4124/xx
Channel Selector
Mains
Audio In 2
Audio Out 2
230
115: 100-120V
50-60Hz
T2.5A 250V
230: 220-240V
50-60Hz
T2A H 250V
2 m (6.5 ft)
100 m (328 ft)
100 m (328 ft)
Regenerative
tap-offs
240 m (787 ft)
Max. P = 25 W at
240 m (787 ft) acc.
to the graph.
The first trunk splitters
use 2.6 W, therefore
the power left at
this point is 22.4 W.
LBB 4114/00
Trunk Splitter
250 m (820 ft) (max)
LBB 4120/00
Interpreter Desk
5 x 2 = 10 m
(32.8 ft)