Parameterisation

3
Parameterisation
3.1

Overview of parameters

Module and channel parameters are available to adapt the module to the situation of use.
General settings that affect the entire module are made using module parameters.
Channel-specific settings are made separately for each channel using the channel parameters.
Module parameters
Diagnostics of sensor supply short circuit
Behaviour after SCS
Input debounce time
Signal extension time
Reserved
1) Function number (è Description of automation system CPX-E); m = module number (counted from left to right, starting from 0)
Tab. 10 Overview of module parameters
Channel parameters
Selection of signal extension time (channel
 7)
...
Selection of signal extension time (channel
 15)
...
1) Function number (è Description of automation system CPX-E); m = module number (counted from left to right, starting from 0)
Tab. 11 Overview of channel parameters
12
Function number
1)
4828 + 64m + 0
4828 + 64m + 1
4828 + 64m + 2 
 5
...
Function number
1)
4828 + 64m + 6
4828 + 64m + 7
Festo — CPX-E-...DI-... — 2020-01a
Detailed information
Tab. 12
è
Tab. 13
è
Tab. 14
è
Tab. 15
è
Detailed information
Tab. 16
è
Tab. 17
è