Parameterisation
3.2

Module parameters

3.2.1

Diagnostics of sensor supply short circuit

The "Diagnostics of sensor supply short circuit" defines whether the diagnostics of the sensor supply
in regard to short circuit or overload should be activated or deactivated.
When the diagnostics are activated, the error will be sent to the bus module and displayed on the
module by the error LED.
Module parameter – Diagnostics of sensor supply short circuit
Setting
Deactivate diagnostics
Activate diagnostics
1) Function number (è Description of automation system CPX-E); m = module number (counted from left to right, starting from 0)
Tab. 12
3.2.2

Behaviour after SCS

The "Behaviour after SCO" parameter defines whether the voltage remains switched off or automatic-
ally switches on again after a short circuit or overload of the sensor supply.
In the case of the "Leave power switched off" setting, the CPX-E automation system must be switched
off and on to restore the power.
Module parameter – Behaviour after SCS
Setting
Leave power switched off
Reactivate voltage auto-
matically again
1) Function number (è Description of automation system CPX-E); m = module number (counted from left to right, starting from 0)
Tab. 13
Festo — CPX-E-...DI-... — 2020-01a
Selection via software
No diagnostics
Diagnostics (default)
Selection via software
Power remains switched
off
Automatic restore
(default)
Selection via parameter
F no.
Bit
1)
4828 +
7
6
5
64m
+ 0
+ 0
Selection via parameter
F no.
Bit
1)
4828 +
7
6
5
64m
+ 1
+ 1
4
3
2
1
0
0
1
4
3
2
1
0
0
1
13