Attach Return Adapter; Connecting Hose Line For Return Quantity And Injection Quantity - Bosch CRI 848H Original Instructions Manual

Test set for testing common rail injectors
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 51
en
82 | CRI/CRIN 848H | Preparing for testing
5.3.4

Attach return adapter

Attach return adapter to injector.
Return adapter for injectors with divided return quantity
2
Fig. 65:
Adapter for injectors with divided return quantity.
1 Return adapter
2 Injector
Return adapter for injectors with internal thread
1
2
Fig. 66:
Adapter for return with internal thread
1 Injector
2 Return adapter
|
1 689 989 087
2018-07-24
1
5.3.5
Connecting hose line for return quantity and
injection quantity
!
Pay attention to correct assignment of the measure-
ment channels when connecting the return quantity
and injected quantity hoses.
i
The following connection diagram for the EPS 708
(Fig. 67) or the EPS 815 (Fig. 68) is based on injec-
tor "A" by way of example. The connection for the
other injectors (B, C, D, E and F) is identical.
Connect the injector to the EPS 708 or EPS 815.
6
5
4
3
2
458847-19_Pal
Fig. 67:
Connection diagram for commercial vehicle injectors on
EPS 708 (without high-pressure connection)
1 Hose line for injection quantity
2 Injection chamber
3 Injector
4 Hose line for return quantity
5 EPS 708 injected quantity connection CRI/CRI piezo
6 EPS 708 return quantity connection CRI/CRI piezo
Included in scope of delivery of EPS 708.
1)
1 2
A
B
1
1)
Robert Bosch GmbH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crin 848h

Table of Contents