Installing The Cooling Shroud - Dell E30S Series Owner's Manual

Table of Contents

Advertisement

Next steps
1. Install the cooling shroud.
2. If required, install the full-length PCIe card.
3. Follow the procedure listed in the After working inside your system section.

Installing the cooling shroud

Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that are shipped with your product.
1. Follow the safety guidelines listed in the Safety instructions section.
2. Follow the procedure listed in the Before working inside your system section.
CAUTION:
Do not operate the system with the cover removed for a duration exceeding 5 minutes.
For proper seating of the cooling shroud in the system chassis, ensure that the cables inside the system are routed
NOTE:
along the chassis wall and secured using the cable securing clips.
Steps
1. Align the slots on the cooling shroud with the tabs on the internal cooling fan.
2. Lower the cooling shroud into the system until the slots on the cooling shroud are flush with the tabs on the internal cooling
fan.
When the cooling shroud is properly seated, the chassis intrusion-switch on the cooling shroud connects to the
NOTE:
chassis intrusion-switch connector on the system board.
Figure 28. Installing the cooling shroud
1. chassis intrusion switch
2. touch points (2)
Installing and removing system components
85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge t430

Table of Contents