2.5.3 Grounding the Device
1.
2.
3.
2.5.3

Grounding the Device

The RUGGEDCOM RSG2488 chassis ground terminal uses an M3 screw. It is
recommended to terminate the ground connection with an M3 ring or spade lug and
torque it to 1.7 N·m (15 lbf-in).
1
1
2
16
Connect the positive wire from the power source to the positive terminal on the
terminal block.
4
1
3
5
Screw-Type Terminal Block for 24 and 48 Power Supply
1
Pluggable Terminal Block for 24P and 48P Power Supply
2
Positive Terminal for PS1
3
Negative Terminal for PS1
4
Positive Terminal for PS2
5
Negative Terminal for PS2
6
Chassis Ground
7
Figure 2.7
DC Terminal Block Wiring
Connect the negative wire from the power source to the negative terminal on
the terminal block.
Connect the ground terminal on the power source to the ground terminal on the
device. For more information, refer to