Grounding The Device; Connecting Power - Siemens SIMATIC NET RUGGEDCOM RS400F Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS400F:
Table of Contents

Advertisement

Figure 2.5
2.5

Grounding the Device

The RUGGEDCOM RS400F chassis ground terminal uses a #6-32 screw. It is
recommended to terminate the ground connection with a #6 ring lug and torque it
to 1.7 N·m (15 lbf·in).
1
2
3
Figure 2.6
2.6

Connecting Power

The RUGGEDCOM RS400F supports a single integrated high AC/DC or low DC power
supply
Note
RUGGEDCOM RS400F
Installation Manual, 11/2022, C79000-G8976-1341-06
1
2
3
Failsafe Alarm Relay Wiring
1
Stainless Steel Stud
#6-32 Screw
#6 Ring Lug
Chassis Ground Connection
For 88-300 VDC rated equipment, an appropriately rated circuit breaker must be
installed.
2
3
Installing the Device
2.5 Grounding the Device
13