Connecting Low Dc Power - Siemens RUGGEDCOM RSG2488 Installation Manual

Rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RSG2488:
Table of Contents

Advertisement

1.
2.
3.
2.5.2

Connecting Low DC Power

To connect a low DC power supply to the device, do the following:
Note
The screw-type terminal block is installed using Phillips screws and compression
plates, allowing either bare wire connections or crimped terminal lugs. Use #6 size
ring lugs for secure, reliable screws, which must be removed to make connections.
RUGGEDCOM RSG2488
Installation Manual, 07/2021, C79000-G8976-1048-11
Connect the positive wire from the power source to the positive/live (+/L)
terminal on the terminal block.
4
1
3
5
Screw-Type Terminal Block for HIP Power Supplies
1
Pluggable Terminal Block for HI Power Supplies
2
Positive/Live (+/L) Terminal for PS1
3
Neutral/Negative (-/N) Terminal for PS1
4
Positive/Live (+/L) Terminal for PS2
5
Neutral/Negative (-/N) Terminal for PS2
6
Figure 2.6
AC Terminal Block Wiring
Connect the negative wire from the power source to the neutral/negative (-/N)
terminal on the terminal block.
Connect the ground terminal on the power source to the ground terminal on the
device. For more information, refer to
6
"Grounding the Device (Page
Installing the Device
2.5.2 Connecting Low DC Power
3
5
4
6
16)".