Cleaning The Inlet Screen; Cleaning The High-Pressure Filter - WAGNER Brillux PROSPRAY 39 SELECT Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

8.3

Cleaning the inlet screen

The inlet screen will clog and must be cleaned at least once a day.
1. Remove the retaining ring (3) from the foot valve (1) housing.
2. Remove the inlet screen (2) from the foot valve housing (1).
3. Clean thoroughly with the appropriate solvent.
ProSpray 39 Special
GB
1
2
3
43
8.4

Cleaning the high-pressure filter

i
Clean the filter cartridge regularly. A soiled or
clogged high-pressure filter can cause a poor spray
pattern or a clogged tip.
1. Turn the pressure control knob counterclockwise to minimum
pressure.
2. Open the relief valve, valve position PRIME (
3. Switch the unit OFF.
Unplug the power plug from the outlet.
4. Unscrew the filter housing (Fig. 10, Item 1). with a strap
wrench.
5. Pull the filter cartridge (2) from the bearing spring (3).
6. Clean all the parts with the corresponding cleaning agent. If
necessary, replace the filter cartridge.
7. Check the O-ring (4), replace it if necessary.
8. Place the bearing ring (5) against the bearing spring (3). Slide
the filter cartridge (2) over the bearing spring.
9. Screw in filter housing (1) and tighten it as far as possible with
the strap wrench.
1
2
Cleaning the unit (shutting down)
circulation).
5
3
4

Advertisement

Table of Contents
loading

Table of Contents