Technical Data - Bosch Rexroth VT-HNC100 3X Series Operating Instructions Manual

Digital axis control
Table of Contents

Advertisement

46/48
Bosch Rexroth AG

Technical data

Bus system
Functionality
Minimum cycle time
Max. size of the cyclic I/O data
Transmission rate
Interface
Specification
Diagnosis LED
Recommendations for bus operation
14 Technical data
Technical data vary according to the version of the VT-HNC100...3X. A detailed
description of you axis control is available in the data sheet RE 30139.
In addition, you can here find data on the two bus systems PROFINET RT
and EtherNet/IP:
PROFINET RT
PROFINET IO RT Device
Conformance Class A
Protocols (CM, RTC, RTA, ARP, ICMP,
LLDP)
Alarm support
Max. 1 API supported
992 byte (max. 496 496 byte per direction)
Integrated cut-through switch
– 3-port switch (2 x external, 1 x internal)
– Pass-through delay min. 0.9 us / max. 1.4 us
Conformity with the relevant IE standard
2 x port status LEDs (Link, Activity)
1 x module status (red / green)
1 x network status (red / green)
– Separation of the IE network from standard Ethernet network (company network)
– Alternative connection to the superior standard Ethernet company network via router
(e.g. level-3 router)
– Separation of standard Ethernet devices (e.g. PCs) in other partial areas (segments) with
additional integration into the IE network
VT-HNC100...3X | RE 30139-B/12.14
EtherNet/IP
EtherNet/IP adapter
Remote Reset: 0/1
Connection Classes 1/3(Exclusive Owner,
Listen Only)
Unconnected Explixit Messaging
DHCP support
2 ms
100 Mbit/s, full-duplex