Bosch Rexroth VT-HNC100 3X Series Operating Instructions Manual page 36

Digital axis control
Table of Contents

Advertisement

36/48
Bosch Rexroth AG
Assembly
Fig. 19: PROFIBUS DP baud rate
6.4.6 Setting the address switch
The address switch is located at the front side of the housing of the
VT-HNC100...3X
A binary setting of 1 to 127 addresses is possible.
In switch position 0 = boot mode, all data can be transferred.
6.4.7 PROFINET RT / EtherNet IP
Here, the IP address is assigned with WIN-PED® 7. The address switch at the
front side is without any meaning.
Further information is available in the online help of WIN-PED® 7.
6.4.8 PROFIBUS DP with TCP/IP
Here, the IP address is assigned with WIN-PED® 7. The address switch at the
front side is without any meaning.
Further information is available in the online help of WIN-PED® 7.
VT-HNC100...3X | RE 30139-B/12.14