Charge Pump; Charge Pump Selection; Charge Pump Flow And Power Curves, 14/17 Cm3 - Danfoss H1 Technical Information

Axial piston single pumps size 060/068
Hide thumbs Also See for H1:
Table of Contents

Advertisement

Technical Information
H1 Axial Piston Single Pumps, Size 060/068
Technical specifications

Charge pump

Charge Pump Selection

In most applications a general guideline is that the charge pump displacement should be at least 10% of
the total displacement of all components in the system. Unusual application conditions may require a
more detailed review of charge flow requirements. System features and conditions which may invalidate
the 10% guideline include (but are not limited to):
Contact your Danfoss representative for application assistance if your application includes any of these
conditions.

Charge pump flow and power curves, 14/17 cm3

Charge pressure: 20 bar [290 psi]
Viscosity: 11 mm2/s [63 SUS]
Temperature: 80°C [176°F]
Charge pump power requirements
Danfoss | May 2017
Continuous operation at low input speeds < 1500 min
High shock loading and/or long loop lines
High flushing flow requirements
Multiple low speed high torque motors
High input shaft speeds
9.0
6
8.0
7.0
5
6.0
4
5.0
3
4.0
3.0
2
2.0
1
1.0
0
0
0
500
1500
2500
1000
2000
Speed min
-1
(rpm)
Archivierung 01/2018
-1
(rpm)
Charge pump flow
18
60
15
50
12
40
9
30
6
20
3
10
3500
1
3000
4000
0
0
P003 336E
11071685 | BC00000074en-US0701 | 9
500
1500
2500
3500
1000
2000
3000
Speed min
-1
(rpm)
P003 334E
4000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H1 and is the answer not in the manual?

Table of Contents