For Your Safety; Unit Features; Function Description - Pilz PSEN ma1.1p-12 Operating Manual

Table of Contents

Advertisement

PSEN ma1.1p-12

For your safety

}
Do not remove the connector's protective cap until you are just about to connect the unit.
This will prevent potential contamination.

Unit features

}
The actuator PSEN 1.1-10 belongs to the safety switch.
}
Coded actuator
}
Safety switch with 4-pin M8 male connector
}
2 safety contacts (reed contacts - N/O)
}
Design: Square
}
Operation Magnetic
}
Switching voltage 24 VDC
}
Series connection via PSEN ix1 interface
}
ECOLAB tested

Function description

If the actuator is within the response range (safety gate closed), the safety contacts of the
safety switch are closed.
The safety switch is designed for applications in series connections.
Operate the PSEN ma1.1p-12 in conjunction with the following components:
}
Actuator PSEN 1.1-10 (see
}
interface PSEN ix1 (see
}
a connected evaluation device (see
devices [
Operating Manual PSEN ma1.1p-12
22190-EN-04
WARNING!
Loss of safety function due to manipulation of the interlocking device
Manipulation of the interlocking device may lead to serious injury and death.
– You should prevent any possibility of the interlocking device being
manipulated through the use of a spare actuator.
– Keep the substitute actuator in a safe place and protect it from unau-
thorised access.
– If spare actuators are used, these must be installed as described in
Installation [
14].
– If the original actuators are replaced with substitute actuators, the ori-
ginal actuators must be destroyed before disposal.
Order reference [
Order reference [
10]).
18]),
20]) and
Requirements and connection to evaluation