Page 1
PSEN ma1.3n-20 VA PSEN sensor technology Operating Manual-1004513-EN-03...
Page 2
We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
Requirements and connection to evaluation devices ............10 Installation ..........................12 Adjustment ..........................14 Periodic test ..........................15 Dimensions in mm .........................15 Technical details ........................16 Safety characteristic data......................17 Order reference ........................18 System ............................18 Accessories..........................18 EC declaration of conformity ....................19 UKCA-Declaration of Conformity ..................19 Operating Manual PSEN ma1.3n-20 VA 1004513-EN-03...
PSEN ma1.3n-20 VA Introduction Validity of documentation This documentation is valid for the product PSEN ma1.3n-20 VA. It is valid until new docu- mentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
EN ISO 13849 and EN 62061. However, this does not guarantee the functional safety of the overall plant/machine. To achieve the relevant safety level of the overall plant/ machine’s required safety functions, each safety function needs to be considered separ- ately. Operating Manual PSEN ma1.3n-20 VA 1004513-EN-03...
– If substitute actuators are used, these must be installed as described under Installation [ 12]. – If the original actuators are replaced with substitute actuators, the ori- ginal actuators must be destroyed before disposal. Operating Manual PSEN ma1.3n-20 VA 1004513-EN-03...
Function description If the actuator is within the response range (safety gate closed), the safety contacts of the safety switch are closed. Operate the PSEN ma1.3n-20 VA in conjunction with the following components: Actuator PSEN ma1.3-08 VA (see Order reference [...
Assured release distance The offset-independent values for the switching distances are included in the Technical details [ 16]. Lateral and vertical offset Actuator PSEN ma1.3-08/VA Legend [1] Lateral offset [2] Vertical offset [3] Sensing faces Operating Manual PSEN ma1.3n-20 VA 1004513-EN-03...
The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory The safety switch is shown in an unoperated condition. Assignment of the 5- Brown pin connector White Black Grey Blue Operating Manual PSEN ma1.3n-20 VA 1004513-EN-03...
PSEN ma1.3n-20 VA Requirements and connection to evaluation devices For use of PSEN ma1.3n-20 VA in accordance with DIN EN 60947-5-3 an evaluation device must be connected. Connect the PSEN ma1.3n-20 VA either with a certified Pilz evaluation device or with an evaluation device with defined properties...
Page 11
(s. operating manual for the relevant evaluation device). Evaluation device PSENmag Input circuit Input circuit Fig.: Dual-channel connection PSEN ma1.3n-20 VA to the input circuits of an evaluation device Examples for connection to Pilz evaluation devices: PNOZ s3 PSENmag Brown...
Safety switches and actuators must be positioned so that they are secured against a change of position. The safety switch and actuator should only be secured using screws and nuts made of non-magnetic material (e.g. brass or stainless steel). Operating Manual PSEN ma1.3n-20 VA | 12 1004513-EN-03...
Page 13
Do not apply any installation tools (e.g. Pliers) on the surfaces of the switch. The protection type (see Technical details [ 16]) is only achieved when Pilz connec- tion cables are used - these are available as an accessory - and when the connector torque is complied with (see Technical details).
Installation [ 12]. Operating distances may deviate if other arrangements are used. Note the maximum permitted lateral and vertical offset (see Operating distances and Lat- eral and vertical offset [ 8]). Operating Manual PSEN ma1.3n-20 VA | 14 1004513-EN-03...
The safety functions should be checked after initial commissioning and each time the plant/machine is changed. The safety functions may only be checked by qualified personnel. Dimensions in mm Safety switch M12x1 Actuator PSEN ma1.3-08/VA M12x1 Operating Manual PSEN ma1.3n-20 VA | 15 1004513-EN-03...
In accordance with the standard EN 60947-5-2 Frequency 10 - 55 Hz Amplitude 1 mm Shock stress Acceleration Duration 11 ms Airgap creepage Pollution degree Rated insulation voltage 30 V Rated impulse withstand voltage 0,8 kV Operating Manual PSEN ma1.3n-20 VA | 16 1004513-EN-03...
Where standards are undated, the 2017-09 latest editions shall apply. Safety characteristic data NOTICE You must comply with the safety characteristic data in order to achieve the required safety level for your plant/machine. Operating Manual PSEN ma1.3n-20 VA | 17 1004513-EN-03...
This product/these products meet the requirements of the directive 2006/42/EC for ma- chinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Authorised representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany UKCA-Declaration of Conformity This product(s) complies with following UK legislation: Supply of Machinery (Safety) Regu- lation 2008.
Page 20
We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...
Need help?
Do you have a question about the PSEN ma1.3n-20 VA and is the answer not in the manual?
Questions and answers