Page 2
We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
Requirements and connection to evaluation devices ............11 Installation ..........................14 Adjustment ..........................16 Periodic test ..........................16 Dimensions in mm .........................17 Technical details ........................17 Safety characteristic data......................19 Order reference ........................20 System ............................20 EC declaration of conformity ....................20 UKCA-Declaration of Conformity ..................20 Operating Manual PSEN ma1.3b-29 22210-EN-09...
PSEN ma1.3b-29 Introduction Validity of documentation This documentation is valid for the product PSEN ma1.3b-29. It is valid until new document- ation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
Safety regulations Safety assessment Before using a device, a safety assessment in accordance with the Machinery Directive is required. Operating Manual PSEN ma1.3b-29 22210-EN-09...
In safety-related applications, please comply with the mission time T stated in the safety- related characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSEN ma1.3b-29 22210-EN-09...
If the actuator is within the response range (safety gate closed), the safety contacts and the auxiliary contact on the safety switch will be closed and the LED will light. Operate the PSEN ma1.3b-29 in conjunction with the following components: Actuator PSEN ma1.3-08 (see...
The offset-independent values for the switching distances are included in the Technical details [ 17]. Lateral and vertical offset Safety switch and actuator, round design – Safety switch and actuator, round design – plan view side view Operating Manual PSEN ma1.3b-29 22210-EN-09...
Page 9
PSEN ma1.3b-29 Legend [1] Lateral offset [2] Vertical offset [3] Sensing face Actuator PSEN ma1.3-08 Assured operating distance S in mm Lateral offset Vertical offset The stated values are valid at a temperature of 20 °C. Operating Manual PSEN ma1.3b-29 22210-EN-09...
Pin assignment NOTICE The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory. The safety switch is shown in an unoperated condition. Layout of the 6-core cable Brown...
PSEN ma1.3b-29 Requirements and connection to evaluation devices For use of PSEN ma1.3b-29 in accordance with DIN EN 60947-5-3 an evaluation device must be connected. Connect the PSEN ma1.3b-29 either with a certified Pilz evaluation device or with an evaluation device with defined properties...
Page 12
[ of PSEN ma1.3b-29 – Always comply with the max. switching current safety contacts of PSEN ma1.3b-29. Outputs at the evaluation device must only be switched on again when both reed con- tacts at the safety switch have been opened and closed (partial operation lock)
Page 13
PSEN ma1.3b-29 Examples for connection to Pilz evaluation devices: PNOZ s3 PSENmag brown white blue black PNOZmulti PSENmag brown white blue black Auxiliary contact with LED The auxiliary contact and the LED indicate the status of the safety contacts. Actuator in the response range...
Safety switches and actuators – Should be kept away from iron swarf – Should not be exposed to strong magnetic fields Prevent the safety switch and actuator being exposed to heavy shock or vibration. Operating Manual PSEN ma1.3b-29 | 14 22210-EN-09...
Page 15
Note the max. torque setting (see Tech- nical details [ 17]). Installation with actuator PSEN ma1.3-08 Slide the actuator through the hole in the mounting surface with the sensing face to- wards the safety switch. Sensing face Operating Manual PSEN ma1.3b-29 | 15 22210-EN-09...
Periodic test Carry out a monthly function test on the safety switch and actuator. Always test the function with a connected evaluation device. The safety function may only be checked by qualified personnel. Operating Manual PSEN ma1.3b-29 | 16 22210-EN-09...
150 mA Max. switching frequency 1 Hz Lowest operating current (Im) 1 mA Switching voltage 24 V Internal resistance 10 Ohm Max. switching current, safety contacts 0,2 A Max. breaking capacity, safety contacts Operating Manual PSEN ma1.3b-29 | 17 22210-EN-09...
Page 18
2 mm Min. distance between safety switches 25 mm Sensor flush installation in accordance with EN 60947-5-2 yes, follow installation guidelines Connection type 10 m cable Cable LiY11Y 6 x 0.25 mm2 Material Operating Manual PSEN ma1.3b-29 | 18 22210-EN-09...
Sensor, 2-ch, 5mA < I ≤ 60 mA 8.500.000 Sensor, 2-ch, > 60 mA 4.000.000 NOTICE You must comply with the safety characteristic data in order to achieve the required safety level for your plant/machine. Operating Manual PSEN ma1.3b-29 | 19 22210-EN-09...
European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany UKCA-Declaration of Conformity This product(s) complies with following UK legislation: Supply of Machinery (Safety) Regu- lation 2008.
Page 21
We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, E-Mail: info@pilz.com, Internet: www.pilz.com...
Need help?
Do you have a question about the PSEN ma1.3b-29 and is the answer not in the manual?