Ppp/Max Timer; Ppp/Max Failure; Connection List/Dial Out; Dial Out/Number 1 - ADTRAN Express L128 User Manual

Isdn router/bridge
Table of Contents

Advertisement

PPP/Max Timer

Write security: 3; Read security: 5
This value is the number of seconds to wait between unanswered configura-
tion-requests. The possible values are 1 sec, 2 secs (def), 3 secs, 5 secs and 10
secs.

PPP/Max Failure

Write security: 3; Read security: 5
Due to the nature of PPP, configuration options may not be agreed upon be-
tween two PPP peers. This value is the number of configuration-naks that
should occur before an option is configuration-rejected. This allows a connec-
tion to succeed that might otherwise fail. The possible values are 5 (def), 10, 15
and 20.

Connection List/Dial Out

The dialing parameters for establishing this connection are defined under this
menu.

Dial Out/Number 1

Write security: 3; Read security: 5
This is the first number used for dialing up this connection.

Dial Out/Number 2

Write security: 3; Read security: 5
This is the second number used for dialing a second B-channel when adding
bandwidth. If BACP/BAP is negotiated, this number is not necessary. If this
number is not specified and BACP/BAP is not used, the Number 1 number is
re-dialed when adding bandwidth.

Dial Out/Call Type

Write security: 3; Read security: 5
The call type can be configured in four different ways:
Speech - Speech directs the call control software to request a
Mu-law encoded speech circuit as the bearer capability for the
outgoing calls. The speech option is used with an ISDN line
61202.070L1-1
Chapter 3: Terminal Menu Operation and Structure
Express L128/L128T User Manual
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express l128t