Technical data
Category
Electromagnetic
compatibility (EMC)
Mechanical tests
Approvals
Conformity declarations
Ethernet LAN interface
IO-Link
LED indicators
netFIELD sensorEDGE | User manual
DOC200601UM01EN | Revision 1 | English | 2021-09 | Released | Public
Parameter
Radio Interference Field
Strength Emission
Radiated Field Immunity
Conducted Disturbances
Immunity
Radio Interference
Voltage Emission
ESD contact discharge
Burst
Surge
Vibration sinusoidal
Shock
Free fall
UL
CE
UKCA
RoHS
REACH
Type
Connector
Type
Connector
SYS (green/yellow)
Wi-Fi/Bluetooth
(blue)
EDG (red/green)
CLD (red/green)
RUN (red/green)
ERR (red/green)
LINK (green)
ACT (yellow)
1L (red/green)
2L (green)
8 x A (red/green/yellow)
8 x B (red/green/yellow)
Table 39: Technical data sensorEDGE
Value
DIN EN 55016-2-3 / BS EN 55016-2-3
DIN EN 61000-4-3 / BS EN 61000-4-3
DIN EN 61000-4-6 / BS EN 61000-4-6
DIN EN 55016-2-1 / BS EN 55016-2-1
DIN EN 61000-4-2 / BS EN 61000-4-2
4 kV
DIN EN 61000-4-4 / BS EN 61000-4-4
DIN EN 61000-4-5 / BS EN 61000-4-5
DIN EN 60068-2-6:2008 (including monitoring for contact breaks
according to DIN EN 60512-2-5:2004)
DIN EN 60068-2-27:2010 (including monitoring for contact
breaks according to DIN EN 60512-2-5:2004)
DIN EN 60068-2-31:2009
In preparation
Yes
Yes
Yes
Yes
10/100 MBit/s Ethernet port (eth0)
M12, D-coded, female, 4-pin.
Recommended tightening torque of locking screw: 0.4 – 0.6 Nm
IO-Link Master, Class A, 8 ports
8 x M12 A-coded, female, 5-pole
Recommended tightening torque of locking screw: 0.4 – 0.6 Nm
Maximum cable length: 20 m.
"System" status LED of the communication controller
Currently without function (reserved for future use)
"Edge" LED indicating configuration and operating states of the
IO-Link sensors
"Cloud" LED indicating connectivity with the Internet/cloud
Currently without function (reserved for future use)
Currently without function (reserved for future use)
Ethernet Link status
Ethernet Activity status
Indicates supply voltage status
Indicates supply voltage status of second load circuit (U
Note: The sensorEDGE does not need or use auxiliary supply
voltage (U
), even though the 2L LED and the pins for the 2L
2L
auxiliary load circuit are implemented on the device.
Status of the IO-Link port
(Note: Yellow is produced by switching red and green duo LED
on at the same time)
Not used
149/166
).
2L
© Hilscher 2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sensoredge

Table of Contents