Lincoln Electric VRTEX 360 COMPACT Operator's Manual page 46

Hide thumbs Also See for VRTEX 360 COMPACT:
Table of Contents

Advertisement

VRTEX
360 COMPACT
®
SELECTING ROOT OR FACE
Select the direction of the bend to the ROOT or FACE. Once the
desired sample is chosen, press the green BEND icon to begin the
bend test.
Figure 86 – Root
Figure 87 – Face
Once the first sample has been bent, use the white NEXT or PREV
arrow to select the next tab to bend.
Figure 88 – Green to bend
Figure 89 – Completed bend test
BEND TEST FAILURE
The VRTEX will visually inspect the weld before allowing it to be
bent. If the weld passes the visual inspection, the user can proceed
with the bend test. If a weld fails the bend test, the details such
as a percentage of failure will be displayed in the information box
on the right side of the screen. The weld failure is measured in
three different aspects including Lack of Fusion, Porosity, and Slag
Inclusion. If the user fails the bend test there will not be a virtual
bend test certificate in the student report.
Figure 90 – Failed
Figure 91 – Completed bend test
37