14 Inspection and maintenance

WARNING
The equipment is subject to pressure!
▶ Risk of severe injury or death.
Depressurize the plant.
Completely drain the plant.
Use of incorrect spare parts!
▶ Damage to the GEMÜ product.
▶ Manufacturer liability and guarantee will be void.
Use only genuine parts from GEMÜ.
Hot plant components!
▶ Risk of burns.
Only work on plant that has cooled
down.
NOTICE
Exceptional maintenance work!
▶ Damage to the GEMÜ product.
Any maintenance work and repairs not described in these
operating instructions must not be performed without
consulting the manufacturer first.
The operator must carry out regular visual examination of the
GEMÜ products depending on the operating conditions and
the potential danger in order to prevent leakage and damage.
The product also must be disassembled and checked for
wear in the corresponding intervals.
1. Have servicing and maintenance work performed by
trained personnel.
2. Wear appropriate protective gear as specified in plant op-
erator's guidelines.
3. Shut off plant or plant component.
4. Secure plant or plant component against recommission-
ing.
5. Depressurize the plant or plant component.
6. Actuate GEMÜ products which are always in the same po-
sition four times a year.
7. If necessary, the end position counter User can be reset
after maintenance or other changes under parameter
Cycle Counter.
www.gemu-group.com
CAUTION
CAUTION

14.1 Spare parts

Item
A
Actuator
2
Isolating dia-
phragm

14.2 Removing the actuator

1. Move the actuator A to the open position.
2. Loosen the fastening elements between actuator A and
body 1 diagonally and remove them.
3. Remove the washers 27.
4. Remove actuator A from control mechanism 4.
Important:
▶ After disassembly, clean all parts of contamination. Take
care not to damage the parts in the process. Afterwards,
check parts for potential damage. If parts are damaged,
replace them.
5. Move the actuator A to the closed position.

14.3 Mounting the actuator

1. Move the actuator A to the open position.
2. Place actuator A onto control mechanism 4.
3. Lay the washers 27 over the stud bolts 25.
4. Screw in the fastening elements until hand tight and
tighten diagonally with a suitable open-end wrench (for
torques see table).
47 / 57
14 Inspection and maintenance
A
2
Name
Order description
9566...
566 000 PAM 4/33
NOTICE
GEMÜ 566
Code S0

Advertisement

Table of Contents
loading

This manual is also suitable for:

566 p566 m566 e566 8d 1c133c1s5g 63 0a566 10d 1c13301tng1600566 15d88c1 411t1g 100 ... Show all

Table of Contents