GEM 566 Series Operating Instructions Manual page 51

Motorized control valve
Table of Contents

Advertisement

14.5.3 Assembly without assembly tool
3
2
29
21
1. Connect the isolating diaphragm 2 to the regulating cone
3 and nut 29.
2. Position a WAF 17 open-end wrench on the regulating
cone 3.
3. Simultaneously, position a WAF 18 open-end wrench on
the nut 29.
4. By counterholding both open-end wrenches, carefully
screw the regulating cone 3 and the nut 29 to the isolating
diaphragm 2.
5. Mount the regulating cone (see chapter "Mounting the reg-
ulating cone").
14.5.4 Assembly with assembly tool
3
2
29
21
1. Connect the isolating diaphragm 2 to the regulating cone
3 and nut 29.
2. Insert nut 29 into the recess on the assembly tool.
3. Position a WAF 17 open-end wrench on regulating cone 3
and turn it clockwise. Then screw together nut 29 and isol-
ating diaphragm 2.
4. Mount the regulating cone (see chapter "Mounting the reg-
ulating cone").
14.6 Cleaning the product
Clean the product with a damp cloth.
Do not clean the product with a high pressure cleaning
device.
www.gemu-group.com
30
30
30
30
51 / 57
14 Inspection and maintenance