CONTROL VALVE PROGRAMMING AND COVER DRAWING MANUAL

INSTALLER DISPLAY SETTINGS

STEP 1I
STEP 2I
STEP 3I
STEP 4I
STEP 5I
STEP 6I
STEP 7I
STEP 8I
RETURN TO NORMAL MODE
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2021
STEP 1I - Press NEXT and ▲ simultaneously for 3 seconds.
STEP 2I – Display Language – Select between English, German or Ukranian.
Press NEXT to go to Step 3I. Press REGEN to exit Installer Display Se�ngs.
STEP 3I – Hardness: Set the amount of hardness in grains of hardness as calcium carbonate per
meq/l, PPM, or dH° using ▼ or ▲. This display will not appear if "FILTERING" is selected in Step
3SS or if OFF or a number is set in Step 9SS. Press NEXT to go to Step 4I. Press REGEN to exit
Installer Display Se�ngs.
STEP 4I – Service Hardness - This display will only appear if Step 10CS MIXING VALVE is set
to ON.
Press NEXT to go to Step 5I. Press REGEN to return to previous step.
STEP 5I – Day Override: When volume capacity is set to "OFF", sets the number of days between
regenera�ons. When volume capacity is set to AUTO or to a number, sets the maximum number of
days between regenera�ons. If value set to "OFF", regenera�on ini�a�on is based solely on volume
used. If value is set as a number (allowable range from 1 to 28) a regenera�on ini�a�on will be
called for on that day even if suffi cient volume of water were not used to call for a regenera�on. Set
Day Override using ▼ or ▲:
• number of days between regenera�on (1 to 28); or
• "OFF".
See Se�ng Op�ons Table for more detail on setup. Press NEXT to go to Step 6I. Press REGEN to
return to previous step.
STEP 6I – Next Regenera�on Time (hour): Set the hour of day for regenera�on using ▼ or ▲. The
default �me is 2:00. This display will not appear if "IMMEDIATE" is selected in Set Regenera�on
Time Op�on in OEM So�ener System Setup Step 7SS. Press NEXT to go to Step 7I. Press REGEN
to return to previous step.
STEP 7I – Next Regenera�on Time (minutes): Set the minutes of day for regenera�on using ▼ or
▲. This display will not be shown if "IMMEDIATE" is selected in Set Regenera�on Time Op�on
in OEM System Setup Step 7SS. Press NEXT to go to Step 8I. Press REGEN to return to previous
step.
STEP 8I – As an energy-saving feature, the control will automa�cally turn off the display
illumina�on a�er 5 minutes of keypad inac�vity. Any further keypad ac�vity or water use will
re-illuminate the display for 5 minutes. The Energy Saver feature default is ON.
Press NEXT to exit Installer Display Se�ngs. Press REGEN to return to previous step.