CONTROL VALVE PROGRAMMING AND COVER DRAWING MANUAL
Page 16
SETTING OPTIONS TABLE. FILTERS SHOULD ONLY USE SHADED OPTIONS.
Volume
Regenera�on
Capacity
Time Op�on
DELAYED
AUTO
REGEN
DELAYED
AUTO
REGEN
Any
DELAYED
number
REGEN
DELAYED
OFF
REGEN
Any
DELAYED
number
REGEN
AUTO
IMMEDIATE
Any
IMMEDIATE
number
AUTO
BOTH
AUTO
BOTH
Any
BOTH
number
Reserve capacity es�mate is based on history of water usage. Reserve Capacity es�mate is not available with
1
alternator systems or Twin Tank Valve.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2021
Day
Override
Reserve capacity automa�cally es�mated.
OFF
Regenera�on occurs when volume capacity falls below the reserve
capacity at the next Regen Set Time
Reserve capacity automa�cally es�mated.
Any
Regenera�on occurs at the next Regen Set Time when volume capacity
number
falls below the reserve capacity or the speci fi ed number of days
between regenera�ons is reached.
Reserve capacity not automa�cally es�mated.
OFF
Regenera�on occurs at the next Regen Set Time when volume
capacity reaches 0.
Reserve capacity not automa�cally es�mated.
Any
Regenera�on occurs at the next Regen Set Time when the speci fi ed
number
number of days between regenera�ons is reached.
Reserve capacity not automa�cally es�mated.
Regenera�on occurs at the next Regen Set Time when volume
Any
capacity reaches 0 or the speci fi ed number of days between
number
regenera�ons is reached.
Reserve capacity not automa�cally es�mated.
Regenera�on occurs immediately when volume capacity reaches 0.
OFF
Time of regenera�on will not be allowed to be set because
regenera�on will always occur when volume capacity reaches 0.
Reserve capacity not automa�cally es�mated.
Regenera�on occurs immediately when volume capacity reaches 0.
OFF
Time of regenera�on will not be allowed to be set because regenera�on
will always occur when volume capacity reaches 0.
Reserve capacity automa�cally es�mated.
Regenera�on occurs when volume capacity falls below the reserve
OFF
capacity at the next Regen Set Time or regenera�on occurs a�er 10
minutes of no water usage when volume capacity reaches 0.
Reserve capacity automa�cally es�mated.
Regenera�on occurs at the next Regen Set Time when volume capacity
Any
falls below the reserve capacity or the speci fi ed number of days
number
between regenera�ons is reached or regenera�on occurs a�er
10 minutes of no water usage when volume capacity reaches 0.
Reserve capacity not automa�cally es�mated.
Any
Regenera�on occurs at the next Regen Set Time when the speci fi ed
number
number of days between regenera�ons is reached or regenera�on occurs
a�er 10 minutes of no water usage when volume capacity reaches 0.
CE Man u al
Result
1
15