Program Settings - Ecosoft MO6500BWTSS Instruction Manual

Ro system
Table of Contents

Advertisement

INSTRUCTION MANUAL ECOSOFT RO SYSTEM MO6500BWTSS
18

8.4. PROGRAM SETTINGS

Configuration settings are stored in non-volatile memory. Access to each submenu is protected
with passcode. To enter configuration menu, hold
storing values is helped by flashing cursor.
STOP button increments selected digit by one, cycles between options, or scrolls to the next
screen when the cursor is at the '>' symbol.
MENU
SETTINGS
1. SETTINGS AND CALIBRATION PASSCODE PROMPT
1.0 Language
1.1 High pressure pump delay, s
1.2 Forward Flush 1 duration, s
1.3 Forward Flush 2 duration, s
1.4 High pressure pump power during Forward Flush 2, on/off
1.5 Frequency of periodic Forward Flush in Service, h
1.6 Frequency of periodic Forward Flush in Standby, h
1.7 Read low feed pressure during Forward Flush, on/off
1.8 Low feed pressure switch, NO/NC
1.9 Low feed pressure Fault delay, s
1.10 High feed pressure switch, NO/NC
1.11 Permeate backpressure switch, NO/NC
1.12 Backpressure Standby delay, s
1.13 Tank level switch, NO/NC
1.14 Tank level Standby delay, s
1.15 Display TDS in ppm
1.16 Permeate conductivity Fault threshold, μS/cm
1.17 Permeate conductivity Fault delay, s
1.18 Display temperature
1.19 New settings and calibration passcode
2. SETTINGS AND CALIBRATION PASSCODE PROMPT
2.1 First point value, μS/cm
2.2 Second point value, μS/cm
3. MAINTENANCE PASSCODE PROMPT
3.1 Schedule maintenance stop, on/off
3.2 Scheduled stop period, h (if 3.1 is set to 'on')
3.3 New maintenance passcode
*During the first run of the R.O. unit, the parameter can be increased to the maximum value in order to vent
the air and fill the system with water. Make sure to revert it back to the factory setting of 10 sec.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2021
STOP for 8 seconds. In the menu, editing and
START button moves cursor one position to the right,
FACTORY SETTINGS
0000
English
10 s*
60 s
0 s
off
4 hour
24 hour
on
NC
3 s
NO
NC
1 s
NC
1 s
off
0 μS/cm
0
C
-
0000
-
-
0000
off
500 h